Operation Instructions Rockhopper 3 Extreme
CHAPTER 4 : PERIODICAL MAINTENANCE
34
4.1.2.2 Replacing the sponge in the spitting box.
Notes
Use gloves and tweezers to change the absorbent in the flushing box.
Step 1 : Go to the WiperClean menu and DON’T press enter when in it.
Going to the WiperClean menu will unlock the head
Step 2 : The carriage moves to the waiting position for replacing the flushing sponge.
Step 3 : Remove the old absorbents with tweezers. (See image below)
1 = Sponge (KY-42889)
2 = Tweezers
3 = Gloves
Step 4 : Install the new absorbents in the flushing box.
Notes
Make sure that the 2 holes are on the right side of the flushing box and that the pins of the black box
are in the holes of the absorbent.
1 = Two holes
2 = Pin of black box
Step 5 : Close the front cover and press the [ENTER] key in the active display (=WiperClean menu). The
head will cap in and be locked.